Home » Vacuum Component » Vacuum Pump » Multi-Stage Roots Type Dry Vacuum Pump ECO-SHOCK:ES10
| Model | ES10 | |
| Power supply | Voltage, frequency, phase | 100 to 220 VAC, 50 / 60 Hz, single-phase |
| Power consumption | 65W(Reading when pressure is at ultimate puressure, and gas for shaft seal and gas ballast are 0 Pa・m3/s) |
|
| Control | Input | Remote start / stop (DC 24V contact with voltage) Non-voltage contact with contact capacity of 2.0 A Min. required |
| Output | Overcurrent alarm output (non-voltage contact) Contact capacity : DC 24V, 1.0 A |
|
| Operation | Manual start switch | |
| Display | Display of operation time | |
| Appearance | Dimensions | Eco-Shock:175mm×310mm×240mm Valve unit:Φ66mm×110mm(NW40) |
| Weight | Eco-Shock:8.3kg Valve unit:800g | |
| Connection | Connection port | G1/4″ (INLET、OUTLET) The connector has been installed. |
| Recommended piping | Φ : 6.53 mm Min. Length : 3 m Max. |
|
| Manufacturer | ULVAC | ||
| Model | LR60 | LR90 | LR180 |
| Evacuation speed *1 | 1300L/min | 2100L/min | 3980L/min |
| Measured power consumption *2 |
2.1kW | 3.6kW | 6.6kW |
| Measured power consumption with ECO-SHOCK attached *2 *3 *4 |
0.7kW | 1.0kW | 1.6kW |
| Power reduction rate | 67% | 72% | 76% |
*1 At 60Hz power.
*2 Power consumption at ultimate pressure.
*3 Including power consumption of ECO-SHOCK.
*4 Reading at ultimate pressure, with shaft seal and gas ballast at 0Pa・m3/s. These valves change slightly depending on the gas flow at ballast and shaft seal.
Copyright © ULVAC INDIA. All rights reserved.